{"id":2491,"date":"2014-09-15T11:07:12","date_gmt":"2014-09-15T11:07:12","guid":{"rendered":"http:\/\/www.sanitaryvalvefittings.com\/?p=2491"},"modified":"2017-03-16T08:57:29","modified_gmt":"2017-03-16T08:57:29","slug":"self-priming-pumpscip-pumps","status":"publish","type":"post","link":"https:\/\/www.sanitaryvalvefittings.com\/es\/bombas-autocebantes\/","title":{"rendered":"Bombas autocebantes (bombas CIP)"},"content":{"rendered":"<hr \/>\n<h1>Bomba autoaspirante (Bomba CIP)<\/h1>\n<p><strong>Bomba autoaspirante<\/strong> es un dise\u00f1o higi\u00e9nico de canal lateral <a title=\"bomba sanitaria\" href=\"https:\/\/www.sanitaryvalvefittings.com\/es\/categoria\/bombas-sanitarias\/\">bomba sanitaria<\/a>Es aplicable en la industria alimentaria, biofarmac\u00e9utica y qu\u00edmica. <em>Bomba autocebante<\/em> est\u00e1 especialmente dise\u00f1ado para bombear materiales que contengan aire o gas, y tambi\u00e9n puede utilizarse para aspiraci\u00f3n negativa con cebado previo, as\u00ed como con equipos de filtraci\u00f3n. Wellgreen <em>bomba autocebante<\/em> puede utilizarse para vino, aceite fino, jarabes, productos vol\u00e1tiles como alcohol, acetona y otros disolventes, u otros materiales cuya temperatura se aproxime al punto de ebullici\u00f3n. Sin embargo, el campo de uso principal de <em>bomba autocebante<\/em> es para la devoluci\u00f3n del PIC.<\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #993300;\">Dise\u00f1o y caracter\u00edsticas<\/span><\/h3>\n<ul class=\"list-style\">\n<li>La cubierta del motor es de chapa conformada en fr\u00edo.<\/li>\n<li>Cuerpo de entrada y rodete de fundici\u00f3n de acero inoxidable.<\/li>\n<li>El sellado mec\u00e1nico evita el contacto entre los muelles y el fluido bombeado.<\/li>\n<li>Soporte de acero inoxidable<br \/>\n.<\/li>\n<\/ul>\n<h3><span style=\"color: #993300;\">Materiales<\/span><\/h3>\n<ul class=\"list-style\">\n<li>Partes h\u00famedas: AISI 316\/304<\/li>\n<li>Otras piezas: AISI 304<\/li>\n<li>Juntas (est\u00e1ndar): EPDM(FDA)<\/li>\n<li>Sellado mec\u00e1nico (est\u00e1ndar): C\/SiC\/EPDM<\/li>\n<li>Acabado de la superficie interna: Pulido<\/li>\n<li>Acabado de la superficie exterior: Chorro de arena<\/li>\n<\/ul>\n<h3><span style=\"color: #993300;\">Especificaciones t\u00e9cnicas<\/span><\/h3>\n<ul class=\"list-style\">\n<li>Caudal m\u00e1x. : 30m\u00b3\/h 132GPm<\/li>\n<li>Cabeza m\u00e1x. : 30H(M)<\/li>\n<li>Presi\u00f3n m\u00e1x. : 3Bar\/43PSI<\/li>\n<li>Temp. m\u00e1x. de funcionamiento : 120\u00b0C\/248\u00b0F<\/li>\n<li>Velocidad de giro m\u00e1x. : 1750 min<\/li>\n<li>Altura m\u00e1x. de aspiraci\u00f3n : 8 m\/22 pies<\/li>\n<\/ul>\n<h3><span style=\"color: #993300;\">Principios de funcionamiento<\/span><\/h3>\n<p>El impulsor est\u00e1 alojado entre el cuerpo de admisi\u00f3n y la carcasa de riesgo, gira conjuntamente con el eje de la bomba. La rotaci\u00f3n del impulsor y la disposici\u00f3n del canal lateral, crea una presi\u00f3n negativa en el interior del cuerpo de admisi\u00f3n, que genera la fuerza de succi\u00f3n de la bomba. Al mismo tiempo, el fluido recibe energ\u00eda en forma de energ\u00eda cin\u00e9tica y energ\u00eda de presi\u00f3n, y esto lo impulsa a trav\u00e9s de la carcasa del impulsor.<\/p>\n<h3><span style=\"color: #993300;\">Opciones<\/span><\/h3>\n<ul class=\"list-style\">\n<li>Sellado mec\u00e1nico en SiC\/SiC<\/li>\n<li>Juntas de FPM(Viton) y PTFE<\/li>\n<li>Conexi\u00f3n de entrada y salida: Tri-Clamp, Roscada, Bridada a DIN, SMS, 3A, RJT etc.<\/li>\n<\/ul>\n<hr \/>\n<p><a href=\"https:\/\/www.sanitaryvalvefittings.com\/wp-content\/uploads\/2014\/09\/Sanitary-self-priming-pump-hygienic-cip-pump-wellgreen.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.sanitaryvalvefittings.com\/wp-content\/uploads\/2014\/09\/Sanitary-self-priming-pump-hygienic-cip-pump-wellgreen.jpg\" alt=\"Bombas autocebantes - Bombas CIP\" width=\"360\" height=\"151\" \/><\/a><\/p>\n<h2>Especificaci\u00f3n de bombas autocebantes - Bombas CIP<\/h2>\n<table class=\"table table-bordered table-hover\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">Talla<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">L<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">L1<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">L2<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">L3<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">L4<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">H<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">H1<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">D<\/p>\n<\/td>\n<td valign=\"top\" bgcolor=\"#c0dcc0\" width=\"71\">\n<p align=\"center\">D1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">GT-CIP04<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">610<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">300<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">192<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">77<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">160<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">342<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">209<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">50.5<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">38.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">GT-CIP08<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">610<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">300<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">192<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">77<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">160<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">342<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">209<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">50.5<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">50.8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">GT-CIP10<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">650<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">300<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">278<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">81<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">190<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">406<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">221<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">63.5<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">50.8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">GT-CIP20<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">710<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">330<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">267<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">81<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">216<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">426<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">241<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">63.5<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">63.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">GT-CIP30<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">750<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">368<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">267<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">81<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">216<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">426<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">241<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">76.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"71\">\n<p align=\"center\">63.5<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*Para m\u00e1s informaci\u00f3n sobre <em>bombas autocebantes sanitarias<\/em>por favor <a href=\"mailto:wellgreen@kaysuns.com\">Contacto<\/a>.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>La bomba autocebante, tambi\u00e9n llamada bomba CIP, se utiliza en la industria alimentaria, biofarmac\u00e9utica, qu\u00edmica, etc.<\/p>","protected":false},"author":1,"featured_media":2494,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rank_math_lock_modified_date":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_joinchat":[]},"categories":[17,34],"tags":[138],"taxonomy_info":{"category":[{"value":17,"label":"Sanitary Pumps"},{"value":34,"label":"Sanitary self-priming pump"}],"post_tag":[{"value":138,"label":"Stainless Steel Pumps"}]},"featured_image_src_large":["https:\/\/www.sanitaryvalvefittings.com\/wp-content\/uploads\/2014\/09\/Sanitary-self-priming-pumps-stainless-steel-hygienic-cip-pumps-wellgreen.jpg",356,268,false],"author_info":{"display_name":"hansen_admin","author_link":"https:\/\/www.sanitaryvalvefittings.com\/es\/author\/hansen_admin\/"},"comment_info":0,"category_info":[{"term_id":17,"name":"Sanitary Pumps","slug":"sanitary-pumps","term_group":0,"term_taxonomy_id":17,"taxonomy":"category","description":"","parent":0,"count":4,"filter":"raw","term_order":"0","cat_ID":17,"category_count":4,"category_description":"","cat_name":"Sanitary Pumps","category_nicename":"sanitary-pumps","category_parent":0},{"term_id":34,"name":"Sanitary self-priming pump","slug":"sanitary-self-priming-pump","term_group":0,"term_taxonomy_id":34,"taxonomy":"category","description":"","parent":17,"count":1,"filter":"raw","term_order":"0","cat_ID":34,"category_count":1,"category_description":"","cat_name":"Sanitary self-priming pump","category_nicename":"sanitary-self-priming-pump","category_parent":17}],"tag_info":[{"term_id":138,"name":"Stainless Steel Pumps","slug":"stainless-steel-pumps","term_group":0,"term_taxonomy_id":142,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","term_order":"0"}],"_links":{"self":[{"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/posts\/2491"}],"collection":[{"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/comments?post=2491"}],"version-history":[{"count":7,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/posts\/2491\/revisions"}],"predecessor-version":[{"id":3482,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/posts\/2491\/revisions\/3482"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/media\/2494"}],"wp:attachment":[{"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/media?parent=2491"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/categories?post=2491"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sanitaryvalvefittings.com\/es\/wp-json\/wp\/v2\/tags?post=2491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}